EBL Wide Band calibration
#1
Member
Thread Starter
EBL Wide Band calibration
The WB display on my WUD does not match the reading on my gauge. I am using a AEM 30-0300 and the AEM calibration in the ADC channels setup. I believe the dash gauge is correct because it reads 14.7 in closed loop and the o2 mV is around 500 while the EBL displays AFR's in the 13s. I have the calibration info from AEM so I tried making a custom calibration in the user devices but I'm not getting it right. Someone educate me please!
#3
Member
Thread Starter
Re: EBL Wide Band calibration
It's on the money now. I moved the analog input Sensor ground to the actual senor ground like the instructions state. I was using a more convenient to get to ground before. That put me closer, I just had to tweak the user devices setup. Thanks Rob. My AEM 30-0300 WB works good with 0=7.3125 and 5=19.250.